Journal of Spine & NeurosurgeryISSN: 2325-9701

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

petitobahis

Nucleoplasty with NuCore Injectable Nucleus Replacement for Herniated Lumbar Disc: A Multicenter Study with a Minimum Five-Year Follow-up

Study Design: Multicenter pooled analysis of prospective singlearm clinical trials. Objective: To assess the results of NuCore® Injectable Nucleus in long term. Summary of Background Data: Randomized controlled trials have shown discectomy to be effective in relieving pain due to first-time lumbar disk herniation. However, loss of intervertebral disk height and reherniation is not uncommon. NuCore® material is a synthetic polymer, implanted via injection into the nuclear void at discectomy. A previous mono-center study on 15 patients reported promising 2-year results. Methods: Thirty patients (age 18-60 years) at 4 centers were eligible. All patients underwent standard lumbar microdiscectomy followed by the injection of NuCore® Injectable Nucleus material. Outcomes included leg and back pain (Visual Analogue Scale), function (Oswestry Disability Index), quality-of-life assessed (SF- 36) and disc height (plain radiographs). An independent reviewer analyzed MRIs taken at different time points. Results: Twenty-five patients completed the five-year followup with an average follow-up period of 77 months. Overall four patients were revised due to reherniation of the nucleus, 2 of them within one week after index operation, two of them after >3 years postoperative. Clinical long-term improved in all categories: VAS leg pain decreased from 6.4(SD ± 2.4) pre- op to 1.1 (± 1.5) at latest follow-up. VAS back pain decreased from 4.2 (± 2.9) to 1.8 (± 2.0) and ODI from 42 (± 17) to 10 (± 8). Disc height loss was 15.9% at latest follow-up compared to pre-op. On MRI analysis no relevant reactions of the endplate nor new or worsening of pre-existing Modic changes were seen. Conclusion: Long-term data of patients undergoing nucleus augmentation with NuCore® Injectable Nucleus following lumbar microdiscectomy is favorable and comparable with the literature on outcomes after lumbar microdiscectomy. However, potential advantages such as a slow-down in the degenerative cascade of the disc have to be verified in randomized studies.

Special Features

Full Text

View

Track Your Manuscript

Media Partners

GET THE APP